Skip to main content
SHARE
Publication

Development and Testing of the VITAMIN-B7/BUGLE-B7 Coupled Neutron-Gamma Multigroup Cross-Section Libraries...

Publication Type
Conference Paper
Publication Date
Conference Name
14th International Symposium on Reactor Dosimetry (ISRD-14)
Conference Location
Bretton Woods, New Hampshire, United States of America
Conference Date
-

The U.S. Nuclear Regulatory Commission’s Regulatory Guide 1.190 states that calculational methods used to estimate reactor pressure vessel (RPV) fluence should use the latest version of the Evaluated Nuclear Data File (ENDF). The VITAMIN-B6 fine-group library and BUGLE-96 broad-group library, which are widely used for RPV fluence calculations, were generated using ENDF/B-VI data, which was the most current data when Regulatory Guide 1.190 was issued. We have developed new fine-group (VITAMIN-B7) and broad-group (BUGLE-B7) libraries based on ENDF/B-VII. These new libraries, which were processed using the AMPX code system, maintain the same group structures as the VITAMIN-B6 and BUGLE-96 libraries. Verification and validation of the new libraries was accomplished using diagnostic checks in AMPX, “unit tests” for each element in VITAMIN-B7, and a diverse set of benchmark experiments including critical evaluations for fast and thermal systems, a set of experimental benchmarks that are used for SCALE regression tests, and three RPV fluence benchmarks. The benchmark evaluation results demonstrate that VITAMIN-B7 and BUGLE-B7 are appropriate for use in LWR shielding applications, and meet the calculational uncertainty criterion in Regulatory Guide 1.190.