Skip to main content
SHARE
Publication

FLiNaK Compatability Studies with Inconel 600 and Silicon Carbide...

by Graydon L Yoder Jr, Dane F Wilson, Dennis W Heatherly
Publication Type
Journal
Journal Name
Nuclear Engineering and Design
Publication Date
Page Numbers
172 to 180
Volume
307
A small liquid fluoride salt test apparatus has been constructed and testing conducted to examine the compatibility of SiC, Inconel 600, and a spiral wound gasket material in FLiNaK salt. These tests were conducted to test materials and sealing systems that would be used in a FLiNaK salt test loop. Three months of testing at 700oC was used to assure that these materials and seals would be acceptable operating under expected test loop conditions. The SiC specimens showed little or no change over the test period while the spiral wound gasket material showed no degradation, except for the possibility of salt seeping into the outermost spirals of the gasket. The Inconel 600 specimens showed regions of voiding which penetrated the specimen surface to about 250 m in depth. Analysis indicated that the salt had leached chrome from the Inconel surface as was expected for this material. Because the test loop will have a limited working lifetime, it was concluded that these materials would be satisfactory for loop construction.