Sealed Attics Exposed to Two Years of Weathering in a Hot and Humid Climate...

by William A Miller, Sudhir Railkar, Ming C Shiao, Andre O Desjarlais
Publication Type
Conference Paper
Journal Name
ASHRAE Transactions
Publication Date
Page Numbers
290 to 304
Volume
N/A
Conference Name
Thermal Performance of the Exterior Envelopes of Whole Buildings XIII International Conference
Conference Location
Clearwater, Florida, United States of America
Conference Sponsor
ASHRAE
Conference Date
-

Field studies in a hot, humid climate were conducted to investigate the thermal and hygrothermal performance of ventilated attics and non-ventilated semi-conditioned attics sealed with open-cell and with closed-cell spray polyurethane foam insulation. Moisture pin measurements made in the sheathing and absolute humidity sensor data from inside the foam and from the attic air show that moisture is being stored in the foam. The moisture in the foam diffuses to and from the sheathing dependent on the pressure gradient at the foam-sheathing interface which is driven by the irradiance and night-sky radiation. Ventilated attics in the same hot, humid climate showed less moisture movement in the sheathing than those sealed with either open- or closed-cell spray foam. In the ventilated attics the relative humidity drops as the attic air warms; however, the opposite was observed in the sealed attics. Peaks in measured relative humidity in excess of 80 – 90% and occasionally near saturation (i.e., 100%) were observed from solar noon till about 8 PM on hot, humid days. The conditioned space of the test facility is heated and cooled by an air-to-air heat pump. Therefore the partial pressure of the indoor air during peak irradiance is almost always less than that observed in the sealed attics. Field data will be presented to bring to light the critical humidity control issues in sealed attics exposed to hot, humid climates.