Previous work with both class F and class C fly ash indicated minimal leaching from most fly ashes tested. However, the addition of NOx removal equipment might result in higher levels of ammonia in the fly ash. We have recently been testing fly ash with a wide range of pH (3.7-12.4) originating from systems with NOx removal equipment. Leaching experiments were done using dilute CaCl2
solutions in batch and columns and a batch nitric acid method. All methods indicated that the leaching of heavy metals was different in the highest ammonia sample tested and the high pH sample. However, toxicity testing with the Microtox� system has indicated little potential toxicity in leachates except for the fly ash at the highest pH (12.4). When the leachate from the high pH fly ash was neutralized, toxicity was eliminated.