EFFECTS OF SIZE AND GEOMETRY ON THE EQUIBIAXIAL FLEXURAL TEST OF FINE GRAINED NUCLEAR GRAPHITE...

by Chung-hao Shih, Yutai Kato, Takagi Takashi
Publication Type
Conference Paper
Publication Date
Conference Name
37th International Conference and Expo on Advanced Ceramics and Composites
Conference Location
Daytona beach, Florida, United States of America
Conference Date
-

Reduction of specimen size is an essential requirement for neutron irradiation effect studies of materials since space in nuclear reactors for those studies are often very limited and costly. Reducing the specimen size can dramatically reduce the cost of these studies, the irradiation exposure to personnel involved in post irradiation examination and the volume of radioactive waste.
In this study, 4 specimen sizes were systematically varied to examine the size effect on the equibiaxial flexure test of fine grain nuclear graphite in non-irradiated conditions at room temperature. A statistically significant sample population of 30 was used for each specimen geometry or dimension.
The results showed that the round shaped samples followed weibull distribution with Weibull modulus of 25 to 35. The average strength followed the trend of the weakest link theory. The 2 sizes of square shaped samples had Weibull modulus of 29 and 40. Data from round and square samples agree with others reasonably and collectively follow the Weibull scaling theory.
It is concluded that the equibiaxial flexural test using adequate population of small specimens provides useful and reliable information on the statistical strength properties for fine-grained nuclear graphite materials.