Skip to main content
SHARE
Publication

Experiment Attributes to Establish Tube With Twisted Tape Insert Cooling Performance in Plasma Facing Components...

by Emily B Clark, Emilio Ramirez, Art E. Ruggles, Cory Griffard
Publication Type
Journal
Journal Name
Fusion Engineering and Design
Publication Date
Page Numbers
541 to 549
Volume
100

The modeling capability for tubes with twisted tape inserts is reviewed with reference to the application of cooling plasma facing components in magnetic confinement fusion devices. The history of experiments examining the cooling performance of tubes with twisted tape inserts is reviewed with emphasis on the manner of heating, flow stability limits and the details of the test section and fluid delivery system. Models for heat transfer, burnout, and onset of net vapor generation in straight tube flows and tube with twisted tape are compared. The gaps in knowledge required to establish performance limits of the plasma facing components are identified and attributes of an experiment to close those gaps are presented.