Skip to main content
SHARE
Publication

Fully Ceramic Microencapsulated fuel in prismatic high-temperature gas-cooled reactors: Sensitivity of reactor behavior durin...

Publication Type
Journal
Journal Name
Nuclear Engineering and Design
Publication Date
Page Numbers
125 to 147
Volume
345

We conducted reactor performance calculations to assess the potential design basis accident performance of HTGR fuel designs. Three Fully Ceramic Microencapsulated (FCM) fueled HTGR designs were developed in a previous work (Lu et al., 2018). The maximum fuel temperature in the cores fueled by these three FCM fuels was predicted to be higher than that in the reference 350-MWt mHTGR core in both normal operating conditions and during representative design basis accidents (Lu and Brown, 2019). To better understand the potential safety margins in mHTGR design basis accidents, we performed thermal-hydraulics sensitivity studies to investigate how maximum fuel temperature varies considering various parameters, e.g. thermal properties, within the ranges corresponding to the differences between the FCM-fueled prismatic mHTGR cores and the reference core with conventional fuel compacts. We found that the difference in the steady-state axial power distribution contributed the most to the difference in the maximum fuel temperature, in both normal operation and design basis accidents.

Experimental data suggested that the annealing process of irradiation defects in SiC would be rapid at mHTGR relevant fuel temperatures. The bounding potential impact of the SiC annealing on the maximum fuel temperature was analyzed considering both the thermal conductivity recovery and the Wigner energy release due to the annealing of SiC. We found that the defect annealing process in SiC would at most increase the peak maximum fuel temperature of an FCM-fueled core by 40 K in loss of forced cooling accidents and by 10 K in a control rod withdrawal accident. Additional experiments on the SiC defect annealing kinetics and Wigner energy release in more relevant conditions are needed.