Skip to main content
SHARE
Publication

HIGH RESOLUTION EMITTANCE MEASUREMENTS AT SNS FRONT END...

by Alexander V Aleksandrov, Alexander P Zhukov
Publication Type
Conference Paper
Publication Date
Conference Name
LINAC 2012
Conference Location
Tel Aviv, Israel
Conference Date
-

The Spallation Neutron Source (SNS) linac accelerates an H- beam from 2.5MeV up to 1GeV. Recently the emittance scanner in the MEBT (2.5 MeV) was upgraded. In addition to the slit - harp measurement, we now can use a slit installed on the same actuator as the harp. In combination with a faraday cup located downstream in DTL part of the linac, it represents a classical slit-slit emittance measurement device. While a slit – slit scan takes much longer, it is immune to harp related problems such as wire cross talk, and thus looks promising for accurate halo measurements. Time resolution of the new device seems to be sufficient to estimate the amount of beam in the chopper gap (the scanner is downstream of the chopper), and probably to measure its emittance. This paper describes the initial measurements with the new device and some model validation data.