Skip to main content
SHARE
Publication

IDACstar: a MCNP application to perform realistic dose estimations from internal or external contamination of radiopharmaceut...

by Oren Unal, Mauritius M Hiller, Martin Andersson
Publication Type
Journal
Journal Name
Radiation Protection Dosimetry
Publication Date
Page Numbers
406 to 411
Volume
174
Issue
3

A Monte Carlo-based stand-alone program, IDACstar (Internal Dose Assessment by Computer), was developed, dedicated to perform radiation dose calculations using complex voxel simulations. To test the program, two irradiation situations were simulated, one hypothetical contamination case with 600 MBq of 99mTc and one extravasation case involving 370 MBq of 18F-FDG. The effective dose was estimated to be 0.042 mSv for the contamination case and 4.5 mSv for the extravasation case. IDACstar has demonstrated that dosimetry results from contamination or extravasation cases can be acquired with great ease. An effective tool for radiation protection applications is provided with IDACstar allowing physicists at nuclear medicine departments to easily quantify the radiation risk of stochastic effects when a radiation accident has occurred.