Skip to main content
SHARE
Publication

Method for Measurement of TRISO Kernel and Layer Volumes by X-ray Computed Tomography...

by Grant W Helmreich, Michael D Richardson, Singanallur V Venkatakrishnan, Amir K Ziabari
Publication Type
Journal
Journal Name
Journal of Nuclear Materials
Publication Date
Page Number
152255
Volume
539
Issue
1

Layer dimensions are key parameters for as-fabricated tristructural-isotropic (TRISO) particle fuel as well as for post-irradiation examination of particle performance. Layer thicknesses are typically measured by optical microscopy of the particle cross section near mid-plane, while layer volumes are estimated with serial sectioning and microscopy. This method for measuring layer volumes is limited due to the resolution limit imposed by slice thickness and the effect of the polishing process on delicate irradiated particle microstructures. Image processing software has been developed to segregate the three-dimensional (3D) TRISO particle images provided by x-ray computed tomography (XCT) into high-resolution volumetric data for the kernel, all particle layers, and any internal voids introduced during irradiation. These data can be used to analyze key in-reactor behaviors of TRISO particles such as kernel swelling or buffer shrinkage, which are important inputs for fuel performance modeling.