Modeling and Simulation of the ITER First Wall/Blanket Primary Heat Transfer System...

by Alice Ying, Emilian L Popov
Publication Type
Conference Paper
Journal Name
Fusion Science and Technology
Publication Date
Page Numbers
128 to 133
Volume
60
Issue
1
Conference Name
19th Topical Meeting on the Technology of Fusion Energy
Conference Location
Las Vegas, Nevada, United States of America
Conference Sponsor
Amer Nucl Soc Fus Energy Div; US Dept Energy; Atom Energy Soc Japan; Gen Atom; Univ California
Conference Date
-

ITER inductive power operation is modeled and simulated using a thermal-hydraulics system code (RELAP5) integrated with a 3-D CFD (SC-Tetra) code. The Primary Heat Transfer System (PHTS) functions are predicted together with the main parameters operational ranges. The control algorithm strategy and derivation are summarized as well.

The First Wall and Blanket modules are the primary components of PHTS, used to remove the major part of the thermal heat from the plasma. The modules represent a set of flow channels in solid metal structure that serve to absorb the radiation heat and nuclear heating from the fusion reactions and to provide shield for the vacuum vessel.

The blanket modules are water cooled. The cooling is forced convective with constant blanket inlet temperature and mass flow rate. Three independent water loops supply coolant to the three blanket sectors. The main equipment of each loop consists of a pump, a steam pressurizer and a heat exchanger.

A major feature of ITER is the pulsed operation. The plasma does not burn continuously, but on intervals with large periods of no power between them. This specific feature causes design challenges to accommodate the thermal expansion of the coolant during the pulse period and requires active temperature control to maintain a constant blanket inlet temperature.