REAL-TIME CANISTER WELDING HEALTH MONITORING AND PREDICTION SYSTEM FOR SPENT FUEL DRY STORAGE...

by Wei Tang, Stylianos Chatzidakis
Publication Type
ORNL Report
Publication Date

In this report, the salt mist corrosion testing at controlled temperature was carried out successfully on 304L SS submerged arc welded coupons by Unifog Dispersion Tower at ORNL. Corrosion in-situ monitoring system from Intelligent Automation, Inc. (IAI) was setup in the corrosion test and running smoothly to record signals during the corrosion test. Parts and device selection, sensors attachment, and experimental procedures are discussed. There wasn’t any visible corrosion or crack propagation on the weld coupon after about a month of corrosion testing.