Skip to main content
SHARE
Publication

Specific Gamma-Ray Dose Constants with Current Emission Data

by Douglas E Peplow
Publication Type
Journal
Journal Name
Health Physics
Publication Date
Page Numbers
402 to 416
Volume
118
Issue
4

The specific gamma-ray dose constant represents the gamma effective dose rate due to a point source of unit activity of a given nuclide at 1 m. New tabulations of specific gamma-ray dose constants have been made using current gamma emission data from the SCALE 6.2.3 software package and International Commission on Radiological Protection Publication 107, combined with the effective dose per fluence conversion coefficients (antero-posterior orientation) of International Commission on Radiological Protection Publication 116. SCALE data cover 1,264 nuclides, and International Commission on Radiological Protection Publication 107 data include 1,192 nuclides, with only 777 nuclides in common between the two sets.