Skip to main content
SHARE
Publication

STATUS AND PERFORMANCE OF THE SPALLATION NEUTRON SOURCE SUPERCONDUCTING LINAC...

Publication Type
Conference Paper
Publication Date
Page Numbers
4258 to 4260
Conference Name
PAC 07
Conference Location
Albuquerque, New Mexico, United States of America
Conference Date
-

The Superconducting Linac at SNS has been operating with beam for almost two years. As the first operational pulsed superconducting linac, many of the aspects of its performance were unknown and unpredictable. A lot of experience has been gathered during the commissioning of its components, during the beam turn on and during operation at increasingly higher beam power. Some cryomodules have been cold for well over two years and have been extensively tested. The operation has been consistently conducted at 4.4 K and 10 and 15 pulses per second, with some cryomodules tested at 30 and 60 Hz and some tests performed at 2 K. Careful balance between safe operational limits and the study of conditions, parameters and components that create physical limits has been achieved.